CVE-2023-34316
?An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions before 1.0.7) patch, which could allow an malicious user to retrieve file contents.
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2023-34347
?Delta Electronics InfraSuite Device Master versions before 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2023-30765
?Delta Electronics InfraSuite Device Master versions before 1.0.7 contain improper access controls that could allow an malicious user to alter privilege management configurations, resulting in privilege escalation.
Deltaww Infrasuite Device Master
1 Github repository
9.8
CVSSv3
CVE-2022-41772
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
Deltaww Infrasuite Device Master
7.5
CVSSv3
CVE-2022-41776
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an malicious user to provide new values for user configuration files such as UserListInfo.xml. This could lead to the c...
Deltaww Infrasuite Device Master
8.8
CVSSv3
CVE-2022-41778
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserial...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-41779
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, ...
Deltaww Infrasuite Device Master
8.8
CVSSv3
CVE-2023-1134
Delta Electronics InfraSuite Device Master versions before 1.0.5 are affected by a path traversal vulnerability, which could allow an malicious user to read local files, disclose plaintext credentials, and escalate privileges.
Deltaww Infrasuite Device Master
7.8
CVSSv3
CVE-2023-1135
In Delta Electronics InfraSuite Device Master versions before 1.0.5, an attacker could set incorrect directory permissions, which could result in local privilege escalation.
Deltaww Infrasuite Device Master
7.5
CVSSv3
CVE-2023-1136
In Delta Electronics InfraSuite Device Master versions before 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authentication bypass.
Deltaww Infrasuite Device Master
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-32976
CVE-2024-33557
CVE-2024-36801
CVE-2024-35654
authentication bypass
CVE-2024-24919
CSRF
code execution
CVE-2024-27348
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
3
4
NEXT »