8.8
CVSSv3
CVE-2023-1143
In Delta Electronics InfraSuite Device Master versions before 1.0.5, an attacker could use Lua scripts, which could allow an malicious user to remotely execute arbitrary code.
Deltaww Infrasuite Device Master
8.8
CVSSv3
CVE-2023-1144
Delta Electronics InfraSuite Device Master versions before 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation.
Deltaww Infrasuite Device Master
7.8
CVSSv3
CVE-2023-1145
Delta Electronics InfraSuite Device Master versions before 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-41772
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
Deltaww Infrasuite Device Master
7.5
CVSSv3
CVE-2022-41776
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an malicious user to provide new values for user configuration files such as UserListInfo.xml. This could lead to the c...
Deltaww Infrasuite Device Master
8.8
CVSSv3
CVE-2022-41778
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserial...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-41779
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, ...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-41657
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations a...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-38142
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserializat...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-40202
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without...
Deltaww Infrasuite Device Master
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
cross-site scripting
CVE-2024-5158
XML external entity
CVE-2024-4262
CVE-2024-2036
CVE-2024-4985
CVE-2024-21791
remote attackers
CVE-2023-43208
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
NEXT »