Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
schneider-electric interactive graphical scada system vulnerabilities and exploits
(subscribe to this query)
9.8
CVSSv3
CVE-2021-22802
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Dat...
Schneider-electric Interactive Graphical Scada System Data Collector
9.8
CVSSv3
CVE-2022-24312
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attack...
Schneider-electric Interactive Graphical Scada System Data Server
9.8
CVSSv3
CVE-2022-24313
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Ser...
Schneider-electric Interactive Graphical Scada System Data Server
9.8
CVSSv3
CVE-2022-24310
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA...
Schneider-electric Interactive Graphical Scada System Data Server
9.8
CVSSv3
CVE-2022-24311
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when ...
Schneider-electric Interactive Graphical Scada System Data Server
9.1
CVSSv3
CVE-2022-32528
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affecte...
Schneider-electric Interactive Graphical Scada System
9.1
CVSSv3
CVE-2021-22805
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc...
Schneider-electric Interactive Graphical Scada System Data Collector
9.1
CVSSv3
CVE-2021-22823
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc...
Schneider-electric Interactive Graphical Scada System Data Collector
7.8
CVSSv3
CVE-2023-4516
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow a local malicious user to change update source, potentially leading to remote code execution when the attacker force an update containing malicious content.
Schneider-electric Interactive Graphical Scada System
7.8
CVSSv3
CVE-2021-22750
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition.
Schneider-electric Interactive Graphical Scada System
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2023-7073
CVE-2024-5496
CVE-2024-5495
XPath injection
bypass
CVE-2024-30043
CVE-2024-24919
denial of service
CVE-2024-35468
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
5
6
NEXT »