schneider-electric interactive graphical scada system vulnerabilities and exploits
(subscribe to this query)
7.5
CVSSv3
CVE-2021-22824
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Colle...
Schneider-electric Interactive Graphical Scada System Data Collector
7.5
CVSSv3
CVE-2022-24317
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
7.5
CVSSv3
CVE-2022-24314
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
7.5
CVSSv3
CVE-2022-24315
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
7.5
CVSSv3
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider-electric Interactive Graphical Scada System Data Server
7.5
CVSSv3
CVE-2020-7478
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated malicious user to read arbitrary files from the IGSS server PC on an unrestricted or shared netwo...
Schneider-electric Interactive Graphical Scada System
NA
CVE-2013-0657
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and previous versions allows remote malicious users to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
Schneider-electric Interactive Graphical Scada System
Schneider-electric Interactive Graphical Scada System 9.0
2 EDB exploits
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-5248
CVE-2024-3110
CVE-2024-5552
CVE-2024-29415
HTML injection
CVE-2024-3095
TCP
type confusion
CVE-2024-1800
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
« PREV
1
2
3
4
5
6